| External Programming: (PPS-1000 and PPS-2000 Series)
Both the voltage and current can be programmed by an external analog voltage. The outputs are linearly proportional to an external input voltage from 0 to 10 volts with correspondence to the voltage and current full-scale outputs.
To program both voltage and current outpur simultaneously in the external programming mode, two isolated voltage sources are required. Tracking Functions: (PPS-1200 Series)
When the tracking mode is enabled, the voltage and current output of channel two is identical to channel one, and also controlled by channel one.
Dual Range Operation: (PPS-1020 Series)
The PPS-1020 series have two (high/low) operating ranges: high range stands for high current / low voltage output, and low range stands for low current / high voltage output. Remote Sensing:
Up to 0.5 volt can be dropped in each load wire; add 0.5 to 1mV to the voltage load regulation specifications for 0.5 volts drop in the positive load wire.
GPIB Interface Capability: SH1, AH1, T6, TEO, L4, LEO, RL1, SRO, PPO, DC1, DTO, CO, E1
Warranty period: 2 years
Optional Accessory: GPIB Interface Card |