Motech  Nederland
to home to company profile to products to dealers to software update
 
  PPS SERIES SPECIFICATIONS  
 

PPS-1000 Series
PPS-1020 Series
PPS-1200 Series
PPS-2000 Series
Programming Accuracy
main page PPS Series

 
  PPS-1000 Series  
  (70W single output with external programming capability)  
 
PPS1001-1007
1001
0 to 8V/0 to10A
2mV/4mA
1002
0 to 18V/0 to 4A
5mV/2mA
1003
0 to 30V/0 to 2.5A
10mV/1mA
1001
0 to 35V/0 to 2A
10mV/0.6mA
1005
0 to 60V/0 to 1A
20mV/0.4mA
1006
0 to 128V/0 to 0.5A
40mV/0.25mA
1007
0 to 250V/0 to 0.2A
80mV/0.1mA
 
  PPS-1020 Series
top
 
  (100W single output with dual range operation)  
 
PPS1021 -1022
1021
0 to 17.5V or 0 to 35V/
0 to 6A or 0 to 3A
10mV
2mA(high)/1mA(low)
1022
0 to 30V or 0 to 60V/
0 to 3A or 0 to 1.5A
20mV
1mA(high)/0.5mA(low)
 
  PPS-1200 Series  
  (70W per channel/dual outputs)  
 
PPS1201-1206
1201
dual 0 to 8V/0 to 6A
2mV/2mA
1202
dual 0 to 18V/0 to 4A
5mV/1.5mA
1203
dual 0 to 35V/0 to 2A
10mV/0.6mA
1204
dual 0 to 30V/0 to 3A
10mV/1mA
1205
dual 0 to 60V/0 to 1A
20mV/0.4mA
1206
dual 0 to 128V/ 0 to 0.5A
40mV/0.25mA
 
  PPS-2000 Series
top
 
  (180W single output with external programming capability)  
 
PPS2013-2019
2013
0 to 30V/0 to 6A
10mV/2mA
2014
0 to 35V/0 to 5A
10mV/2mA
2015
0 to 8V/0 to 20A
2mV/7mA
2016
0 to 18V/ 0 to 10A
5mV/3mA
2017
0 to 60V/ 0 to 3A
20mV/1mA
2018(A)
0 to 128V/0 to 1.5A(2A)
40mV/0.5mA
2019(A)
0 to 250V/ 0 to 0.8A(1A)
80mV/0.25mA
 
  Programming Accurancy  
  Voltage
Current
0.05% + 2LSB
0.15% + 5LSB
 
  Ripple and Noise    
  Rmis 1mVrms  
  (PPS 1006, 1007, 1206, 2018(A), 2019(A), 3mVrms)  
  Peak-to-peak 10mVp-p  
  Reaback Accuracy    
  Voltage
Current
0.1% + 2LSB
0.2% + 5LSB
 
  Load Regulation    
  Voltage
Current
0.001% + 1mV
1mA
 
  Transient Recovery 50 µs typical  
  Programming Up/Down Speed 15ms/20ms typical  
  Operating Temperature 0 to 40°C  
  Dimensions 8.4" x 5.2" x 15.7"  
  Weight 16 to 20lbs  
 

External Programming: (PPS-1000 and PPS-2000 Series)
Both the voltage and current can be programmed by an external analog voltage. The outputs are linearly proportional to an external input voltage from 0 to 10 volts with correspondence to the voltage and current full-scale outputs.
To program both voltage and current outpur simultaneously in the external programming mode, two isolated voltage sources are required.

Tracking Functions: (PPS-1200 Series)
When the tracking mode is enabled, the voltage and current output of channel two is identical to channel one, and also controlled by channel one.

Dual Range Operation: (PPS-1020 Series)
The PPS-1020 series have two (high/low) operating ranges: high range stands for high current / low voltage output, and low range stands for low current / high voltage output.

Remote Sensing:
Up to 0.5 volt can be dropped in each load wire; add 0.5 to 1mV to the voltage load regulation specifications for 0.5 volts drop in the positive load wire.

GPIB Interface Capability: SH1, AH1, T6, TEO, L4, LEO, RL1, SRO, PPO, DC1, DTO, CO, E1

Warranty period: 2 years

Optional Accessory: GPIB Interface Card

 
  back to main page PPS Series
top
 

Motech Nederland
Pleimuiden 12 E - 1046 AG Amsterdam  Tel: 00-31-(0)20-6146033 Fax: 00-31-(0)20-6144707