Motech Nederland
to home to company profile to products to dealers to software update
 
  200KHz LCR METER
MT 4090
 
 

Specifications
Measurement Range
General
Accessories

MT 4090 LCR Meter

Features:  
  • Measurement Parameters : Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and q.
  • Test conditions : 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz ; 1Vrms, 250mVrms, 50mVrms, 1Vdc (DCR only)
  • DMM Functionalities
  • Dual LCD Display with LED backlit
  • Open / Short calibration
  • Remote binning capability
  • Auto range / range hold selection

Download: MT 4090 LCR Meter PDF file (2.280 kB)
You'll need a copy of Adobe Acrobat (R) Reader to view the PDF files.

 
  Specifications
 
  Test Condition :  
 

Frequency
Level
Measurement Parameters
Basic Accuracy

: 100Hz / 120 Hz / 1KHz / 10KHz / 100KHz / 200KHz
: 1Vrms / 250m Vrms / 50m Vrms / 1Vdc (DCR only)
: Z, Ls, Lp, Cs, Cp, DCR, ESR, D, Q and q
: 0.1 %

 
  Dual Liquid Crystal Display with LED backlit
Auto Range or Range Hold selection
Open / Short Calibration
RS232C Interface
 
  Primary Parameters Display :  
  Z
DCR
Ls
Lp
Cs
Cp
: AC Impedance
: DC Resistance
: Serial Inductance
: Parallel Inductance
: Serial Capacitance
: Parallel Capacitance
 
  Secondary Parameters Display :  
  q
ESR
D
Q
: Angle Impedance
: Equivalent Series Resistance
: Dissipation Factor
: Quality Factor
 
  Combinations of Display :  
  Serial Mode
Parallel Mode
: Z-q, Cs-D, Cs-Q, Cs-ESR, Ls-D, Ls-Q, Ls-ESR
: Cp-D, Cp-Q, Lp-D, Lp-Q
 
  DMM Functionalities :  
  DCV, ACV, DCA, ACA, Diode/Continuity Check  
  Measurement Range
 
 
Z
0.000 W to 500.0 MW
L
0.030mH to 9999.0 H
C
0.003 pF to 80.00 mF
DCR
0.000 W to 500.0 MW
ESR
0.000 W to 9999 W
D
0.000 to 9999
Q
0.000 to 9999
q
-180.0° to 180.0°
V
0.000mV to ± 600.0V
I
0.000mA to ± 2.000A
 
 
top
 
  DC Voltage Measurement:  
  Range
Resolution
Accuracy
Input Impedance
: 2V, 20V, 200V, and 600V
: 1mV, 10mV, 100mV,1V
: ± (0.4% + 3Digit)
: 1MW
 
  AC Voltage Measurement (True RMS):  
  Range
Resolution
Accuracy
Input Impedance
: 2V, 20V, 200V and 600V
: 1mV, 10mV, 100mV, 1V
: ± (0.8% + 5Digit) @ 40Hz ~ 1KHz
: 1MW
 
  DC Current Measurement:    
  Range
Resolution
Accuracy
Current Shun
: 2A, 0.2A, 20mA and 2mA
: 1mA, 0.1mA, 0.01mA and 1µA
: ± (0.4% + 3Digit)
: 0.1W @ current >  20mA
  10W @ current <_ 20mA
 
  AC Current Measurement (True RMS):  
  Range
Resolution
Accuracy
Current Shun
: 2A, 0.2A, 20mA and 2mA
: 1mA, 0.1mA, 0.01mA and 1µA
: ± (0.8% + 5Digit) @ 40Hz ~ 1KHz
: 0.1W @ current >  20mA
: 10W @ current <_ 20mA
 
  Continuity Check:
top
 
 

Continuity Threshold
Continuity Indicator
Input Protection

: 50W ( Approximately )
: Tone Buzzer
: 600V ( max )
 
  Diode Test:    
  Test Current
Open Circuit voltage
Input protection
: 2.5mA ( Typical )
: 5.0VDC ( nominal )
: 600V ( max )
 
  General    
 

Temperature

Relative Humidity
AC Power
Dimensions
Weight

: 0 to 40°C ( Operating )
  -20 to 70°C ( Storage )
: Up to 85%
: 110V / 220V ± 10%, 60/50 Hz
: 300mm x 220mm x 150mm (11.8" x 8.7" x 5.9" ) (D x W x H)
: 4.5 kgs
 
 

Standard Accessories

   
  1. TL09C Kelvin Clips
2. Test Leads

1 pc
1pc

 
  Optional Accessories  
 

3. TL09A SMD test probe
4. TL09B Component fixture

MT 4090 Accessories  
 
top
 

Muco Technologies BV
Pleimuiden 12 E - 1046 AG Amsterdam  Tel: 00-31-(0)20-6146033 Fax: 00-31-(0)20-6144707
Contact us by email