MT1010 SPECIFICATIONS |
|
| |
True rms voltage measurements
True rms current measurements
Inrush measurements
Power measurements
Harmonics measurements
General
Standard Accessories
Optional Accessories
back to main page MT1010 |
 |
|
| |
Frequency Measurements |
|
| |
Range (fundamental) :
Accuracy :
Bandwidth (harmonic) : |
dc, ac ( 10 ~ 100 HZ )
± ( 0.1% + 2 digits )
dc, ac ( 10 HZ ~ 4 KHZ ) |
|
| |
True rms voltage measurements |
|
| |
Input Range : |
2.5V to 900 Vrms ( ac+dc ) ±5.0V to ±1400V ( peak)
|
|
| |
Basic accuracy dc :
or rms(ac or ac+dc) |
± ( 0.2% + 2 digits ) |
|
| |
Crest factor:
Accuracy : |
1.00 ~ 5.00 ± ( 2% + 5digits ) |
|
| |
True rms
current measurements |
|
| |
Direct Current Input: |
|
| |
Input Range : |
250 mA to 30 Arms ( ac + dc ) ± 500 mA to ± 50 A ( peak ) |
|
| |
Basic accuracy dc
or rms(ac or ac+dc) : |
± ( 0.2% + 5 digits ) |
|
| |
Crest factor :
Accuracy : |
1.00 ~ 5.00 ± ( 2% + 5 digits ) |
|
| |
|
|
|
| |
Isolated Current Input ( 1 mVrms / Arms ): |
|
| |
Input Range : |
10.0mVrms (A) to 1400mVrms (A) (ac+dc) ± 20.0 mV to ± 2200 mV (peak) |
|
| |
Basic accuracy dc
or rms(ac or ac+dc) : |
± (0.2% + 2 digits) + probe specs |
|
| |
Crest factor :
Accuracy : |
1.00 ~ 5.00 ± ( 2% + 5 digits ) |
|
| |
Inrush measurements |
|
| |
Voltage Input : |
|
| |
Input Ranges : |
1400V, 640.0V, 160.0V, 40.00V, 10.00V, and 2.500V |
|
| |
Sampling Interval :
Samplings :
Trig Level : |
12.5 Cs
16000 >1/3 Full Range |
|
| |
Direct Current Input : |
|
|
| |
Input Ranges : |
90.00A, 76.80A, 19.20A, 4.800A, 1.200A, and 0.300A |
|
| |
Sampling Interval :
Samplings :
Trig Level : |
12.5 µs
16000 >1/3 Full Range |
|
| |
Isolated Current Input ( 1mV
/ A ) : |
|
| |
Input Ranges : |
2200mV, 1000mV, 250.0mV, 62.50mV, 15.60mV and 3.900mV |
|
| |
Sampling Interval :
Samplings :
Trig Level :
Battery Operating Time : |
12.5 µs
16000
>1/3 Full Range
2.5 Hours typical |
|
| |
Power measurements |
|
| |
Direct Current Input: |
|
| |
Range :
Accuracy :
PF :
Accuracy :
Deg ( £c v - £cI ) :
Accuracy |
0.001 KVA to 27.00 KVA
± (0.5% + 10 digits)
-1.00 to 1.00 ( +=leading PF , -=lagging PF )
± (2% + 3 digits)
-180 to + 180 degree ± (2% + 5 digits) |
|
| |
|
|
|
| |
Isolated Current Input ( 1mV / A ) : |
|
| |
Range :
Accuracy :
PF :
Accuracy :
Deg ( £c v - £cI ) :
Accuracy |
0.025 KVA to 1260 KVA
± (0.5% + 10 digits) + probe specs
-1.00 to 1.00 ( +=leading PF , -=lagging PF )
± (2% + 3 digits) + probe specs
-180 to + 180 degree ± (2% + 5 digits) + probe specs |
|
| |
Harmonics measurements |
|
|
| |
Voltage Input : |
|
| |
Range :
Max harmonic :
Accuracy Fundamental :
Harmonics :
%THD :
Deg (£cFUND - £cHARM) :
Accuracy |
DC and fundamental to 40th harmonic
4 KHZ
± (0.2% + 4 digits)
± (2% + 4 digits)
± (3% + 0.03 x reading)
-180 to +180 degree
2nd ±(1degree)~ 40th ±(20.0 degree) |
|
| |
Direct Current Input : |
|
| |
Range :
Max harmonic :
Accuracy Fundamental :
Harmonics :
%THD :
Deg (£cFUND - £cHARM) :
Accuracy |
DC and fundamental to 40th harmonic
4 KHZ
± (0.2% + 4 digits)
± (4% + 4 digits)
± (4% + 0.03 x reading)
-180 to +180 degree
2nd ±(1degree)~ 40th ±(20.0 degree) |
|
| |
Isolated Current Input : |
|
| |
Range :
Max harmonic :
Accuracy Fundamental :
Harmonics :
%THD :
Deg (£cFUND - £cHARM) :
Accuracy : |
DC and fundamental to 40th harmonic
4 KHZ
± (0.2% + 4 digits) + probe specs
± (4% + 4 digits) + probe specs
± (4% + 0.03 x reading) + probe specs
-180 to +180 degree
2nd ±(1degree)~ 40th ±(20.0 degree) + probe specs |
|
| |
General: |
|
|
| |
Temperature :
Relative Humidity :
Battery Type :
Battery Charge :
Battery Operating Time :
AC Operation :
Low Power Warning :
Dimensions :
Weight : |
0ºC to 40ºC (Operating) -20ºC to 70ºC (Storage)
Up to 85%
Ni-Mh or Alkaline (2xAA size)
Constant current 160mA approximately
2.5 Hours typical
110V/220V AC, 60/50HZ with proper Adapter
under 2.2V
6.9"x3.4"x1.9"(LxWxH) (174mmx86mmx48mm)
470 g |
|
| |
Standard
Accessories |
|
| |
1. MT10A Load Adaptor ( AC 16A 250V w/o shunt )
2. MT10C AC current clamp
3. Test leads ZTP-101MT-1
4. Test leads ZTP-101MT-3
5. Test leads ZTP-101MT-4
6. Clamp-Type clips XTB-1010B&R
7. AA-Size rechargeable battery
8. Carry Case ZCC-200MT-1
9. DC 6V power adaptor |
|
| |
Optional Accessories
|
|
|
| |
10. MT11A Load Adaptor (for low current AC1.6A 250V
w/o Shunt)
11. Test leads ZTP-101MT-2
12. RS232C to infrared adapter |
|
| |
back to main page MT1010 |
|