  MT1010
Power Analyzer
 
  Available Parameters
Low Current Measurement
Direct Measurement Inputs
Test Lead Connection
Specifications

MT1010 Power Analyzer

Characteristics:

Harmonic analysis up to 40th harmonic
14 bits resolution (1W, 1mV, 1mA)
Measure the current down to mA level
Accepts input directly from load adapter or shunts, CT’s and VT’s
Total energy consumption (KWH) measurement
Inrush current and voltage measurements

Target Market
Safety company like UL/CSA/TUV
Lighting Ballast manufacturers
UPS manufacturers
Power Generating plants manufactures
Power Supply Designers
Copy machines repair engineers
Avionics industries

 
 

Nowadays, many household appliances and similar electrical equipment draw current from power supply system in a very non-linear manner and therefore, inevitable introduce disturbances especially harmonics of supply frequencies into the power system to which they are connected.

However, such equipment should not adversely affect the characteristics of power supplies system, the supply voltage or the performance of any other equipment connected to the power supply system.

Given that the members of electronic devices connected to systems seems to increase, the control of harmonic emissions is an obvious requirement.

Therefore, electricians or electrical engineers need not only a tester that would be able to measure, voltage, current and power but a power analyzer that can optimize the harmonic analysis as well.

MT1010, is a handheld Power Analyzer designed with powerful DSP techniques, to provide precise performance of power harmonic analysis to meet the professional needs.The need to quickly and same time accurately analyze your specific power problems and identify the problems sources is what prompted Motech Industries to introduce this new class of instruments.

 
  Available Parameters
top
 
 

Harmonic Analysis

  • up to 40th harmonic
  • total harmonic distortion ( % THD)
  • % fundamental and degree for 1st to 40th harmonic
  • RMS value

Power Analysis

  • total energy consumption (KHW)
  • apparent power (KVA), real power (KW), reactive power (KVAR)
  • true power factor, displacement angle

Voltage and Current

  • frequency
  • trus RMS
  • peak to peak, peak
  • crest factor

Additional features

  • Inrush current & voltage measurements
  • 14 bit resolution with 1W, 1mV and 1mA
  • 0.2% basic accuracy
  • Accepts inputs directly from Load Adaptor or shunts, CT's and VT's
  • Standard infrared interface ( RS232C )
  • AC, DC, AC+DC coupling for power, voltage and current measurements
  • Autorange measurement

Applications

  • Energy consumption of electrical appliances
  • Measurement of maximum and minimum energy demand
  • Harmonic analysis of power factor correction capacitors, variable speed motor drives and solid-state lighting ballasts
  • Efficiency measurements
  • Measurement of Inrush current at switch on
  • Determining power factor and PF correction requirements
 
  Low Current Measurement
top
 
 

MT1010 Power AnalyzerAn optional load Adapter MT11A can be used with MT1010 for the measurement of low current for appliances such as Cell-Phone Charge, AC-to-DC Adapter, UPS and so on.

With the load Adapter, the MT1010 can measure the low current as minimal as mA level. Thus, makes it a very useful instrument applicable to variety of fields. (Remarks:The LCD display readings must be converted into 3 decimal point to get the actual value of the measurement)

 
  Direct Measurement Inputs  
 

MT1010 Power AnalyzerStandard load adapter MT10A is designed to use along with MT1010 for direct measuring input current and voltage during running operations, without interrupting the current path. With this option, users can easily and safely handle the measurement of input current and voltage simultaneously.

 
  Test Lead Connection
top
 
  Connections when Load Adapter is used
MT1010
Single-Phase Power Measurements
MT1010
 
  Connections when CT and PT are used in the measurement
MT1010
Three-Phase Power Measurements

MT1010
 
  Three-Phade, 4 wires Power Measurements

MT1010
   
  Note
top
 
  (a) When Current Transformer ( CT ) is used, the secondary shall not open.
(b) When Potential Transformer ( PT ) is used, the secondary shall not short.
(c) Users shall calculate the ratio when CT and / or PT are used.

 
 
specifications on next page
 