Motech Nederland
to home to company profile to products to dealers to software update
 
  HANDHELD LCR METER
MIC-4070D
 
 

Features
Specifications
General specifications

MIC-4070D

Characteristics:  

The MIC 4070D is an advanced hand-held digital LCR Meter with the ability to measure very low resistance with the 2W range (1mW resolution) and high inductances with 200H range and high capacitances with 20,000µF range.

 

 

 

 

 
  Features
top
 
 
  • 0.1µ H to 200H Inductance Measurement
  • 0.1µ F to 20,000µF Capacitance Measurement
  • 1MW to 20MW Resistance Measurement
  • Dissipation Factor Measurement
  • Zero Adjustment
  • Quick Responding of Measurement
 
  Specifications
 
 

Measurement Range And Accurancy

CAPACITANCE

200pf
1% + 2
0.1pf
Paralled Mode 1KHz 0.5Vrms
2nf
1pf
20nf
10pf
200nf
100pf
2m
1000pf
20mf
0.01mf
Series Mode 120Hz, 1mArms
200mf
0.1mf
Series Mode 120 Hz,10mArms
2mf
2% + 10
1mf
20mf
10mf
 
 
top
 
  DISSIPATION FACTOR

0 ~ 1.999
2000pf
2nf<Cx<2µf
2µf<Cx<2mf
20mf
N.S
1% + 10+ 2000
              Cx
2% + 20 + 2000
               Cx

N.S


Cx is capacitance read-out in counts.
Accuracy is applied when C is from 20 to 100% of full scale range in series mode measurements.
 
 
top
 
  INDUCTANCE

200mH
2% + 2
0.1mH
Series Mode
10mArms, 1KHz
2mH
1% + 2
1mH
10mArms, 1KHz
20mH
10mH
1mArms, 1KHz
200mH
100m H
0.1mArms, 1KHz
2H
2% +2
1mH
Parallel Mode
120Hz, 0.5Vrms
20H
10mH
200H
3% + 2
100mH

The accuracy is applied from 10 to 100% of full scale range in parallel mode measurements.
 
 
top
 
  DISSIPATION FACTOR

0~1.999
Lx < 200mH
200mH < Lx < 200H
1% + 10 + 2000
               Lx
2% + 2 + 2000
             Lx

Lx is inductance read-out in counts.
Accuracy is applied when L is from 20 to 100% of full scale range in parallel mode measurements.
 
 
top
 
  RESISTANCE

2W
1% + 5
1mW
Series Mode 1KHz
10mArms
20W
1% + 2
10mW
10mArms
200W
100mW
1mArms
2KW
1W
0.1mArms
20KW
10W
10mArms
200KW
100W
1mArms
2MW
2% + 2
1KW
Parallel Mode
1KHz, 0.5Vrms
20MW
10KW

Accuracy is ± (% of reading + number of digits) and is applied from 10 to 100% of full scale range in parallel mode measurements.

The specifications given assume an operating temperature of 18°C to 28°C humidity up to 80%, and half year calibration cycle.

 
 

General specifications

top
 
  Power :
Display :
Single 9V 006P battery
0.5 " digital height, 3 1/2 digits liquid crystal display with "LOBAT" and decimal annunicators
 
  Low Battery Warning : Display will show "LOBAT" in the last 5% of battery life  
  Current Consumption : 17.3mA  
  Temperature : 0°C ~ 40°C, Operating
-20°C ~ 70°C, Storage
 
  Dimensions :
Weight :
177x88x40mm
400 grams
 
  Standard Accessories :    
  Test Clips (red & black)
Operation Manual
1 pair
1 piece
 
  Optional Accessories : Measurement clip TL-06 for SMD type component  
 
top
 

Motech Nederland
Pleimuiden 12 E - 1046 AG Amsterdam  Tel: 00-31-(0)20-6146033 Fax: 00-31-(0)20-6144707
Contact us by email