Motech  Nederland
to home to company profile to products to dealers to software update
 
  MIC 2090W
The Ultime Solution for DSL Installation and Maintenance
 
 

Specifications
General Specifications
Accessories

MIC2090W

Features  
  • Measure Power, Current, Voltage, Frequency and Resistance
  • Read True Power (VAcosq), Apparent Power (VA),
    Reactive Power (VAsinq), and Power Factor (cosq)
    Read value of AC,DC, and AC+DC in the signal
  • True RMS or Avg. Scale to RMS Measurement
  • Surge Mode for Inrush Current
  • Data Hold, Max, Min. and Crest Factor Reading
  • Autornage and Manual Operation Selectable
  • 0.8" Digital Height Display, 3500 Counts with Annunciators
 
  Specifications
top
 
  DC Current
35A
1%+15
0.06A
1000A
350A
1%+5
0.2A
1000A
1A

AC Current

47/63Hz
up to 400Hz
35A
1%+15
2%+10
0.03A
1000A
350A
1%+5
0.1A
1000A
1A

Active Power (V x A x COSq)

3.5KW
2%+5
2W
Corresponds to V & A measurements
35KW
20W
350KW
200W
 
  The accuracy applies from 5% - 100% of the range.  
  Apparent Power (VxA)
3.5KVA
2%+5
2VA
Corresponds to V & A measurements
35KVA
20VA
350KVA
200VA
 
  The accuracy applies from 5% - 100% of the range.  
  Reactive Power (V x A x Sinq)
3.5KVar
2%+5
2Var
Corresponds to V & A measurements
35KVar
20VVar
350KVar
200Var
 
  The accuracy applies from 5% - 100% of the range.  
  Reactive Power (V x A x Cosq)
3.5KW
3%+10
0.001
Corresponds to V & A measurements
35KW(<400V)
350KW

Crest Factor (Continuous Waveform 45Hz~65Hz,<1000A peak)
1~6
3%+2
0.001
Corresponds to V&A measurements


AC Voltage (45Hz~400Hz)
350V
1%+5
0.1V
5MW(10pf Shunt)
DC 1000V
AC 750Vrms
600V
1V
 
  The accuracy applies from 5% - 100% of the range.  
  DC Voltage
350V
1%+5
0.2V
5MW
DC 1000V
AC 750Vrms
600V
1V

Surge Mode
ACA
Capture and retain current surge long enough for reading
3%+5
20ms
 
  Note: Aquisition time is the minimum duration of surge for rated accuracy. Accuracy imporves for longer peak duration. The accuracy applies from 5%-100% of the range.  
  Frequency
10Hz-1KHz
0.5%
1Hz
AC/DC 400V

Resistance
0-3.5KW
±1%
1W
AC/DC 400V

Audible Continuity Check
W with . )))
The beeper is triggered if resistance < 30W
±1W
AC/DC 400V
 
  The specifications given assume an operation temperature of 18ºC to 28ºC, humidity up to 80%, and a 1 year calibration cycle. *Accuracy is + (% of reading + number of digits)  
  General Specifications  
  Conductor Size:
Maximum Common Mode Voltage:
Power Source:
Display:
Sample Time:
Power Consumptions:
Operating Temperature:
Storage Temperature:
Dimensions:
Weight:
55ø clamp jaws
500 VDC/peak AC
4 x AAA batteries
4 digits 0.8" high LCD with the annunciators of all functions
0.3 second
240 mw
0 ~ 40ºC
-20 ~ 70ºC
85 x 270 x 43 mm (WxLxH)
700g
 
  Accessories:    
  Test Probes:
Alligator Clips:
Manual:
Carrying Case:
1 pair
1 pair
1 piece
1 piece
 
 
top
 

Motech Nederland
Pleimuiden 12 E - 1046 AG Amsterdam  Tel: 00-31-(0)20-6146033 Fax: 00-31-(0)20-6144707
Contact us by email