FUNCTION
GENERATOR FG 515
15 MHz Sweep FUNCTION GENERATOR |
| |
Key Features
Specifications
Frequency counter 
|
Characteristics: |
|
New FG515, 15MHz Function Generator can generator extremely clean and low distortion waveform output. It comes with 90MHz TTL output, optional 2GHz frequency counter etc.
The unique design is to make the rotary menu driven pop up and down functions for easy operation. Download: Function Generator PDF file (2.287 kB) You'll need a copy of Adobe Acrobat (R) Reader to view the PDF files.
|
|
| |
Key Features |
|
| |
- Rotary menu driven pop up and down function for easy operation
- TTL output
up to 90 MHz
- Low noise signal source
- Optional 2GHz frequency counter
- Triangle, Square, Sine, TTL Sync out, Asymmetry, Ramp up, Log waveforms
and
DC
- Duty cycle up to 15MHz for TTL, resolution 0.1%
- Amplitude attenuation -60dB
|
|
| |
Specifications |
|
|
| |
Function Generator |
|
| |
Waveforms |
: Triangle, Square, Sine, TTL Sync out, Asymmetry, Ramp up, Log Waveforms and DC. |
|
| |
Function Output Range
TTL Output Range
Resolution
Symmetry/duty cycle |
: 0.2Hz ~ 15MHz
: 0.2Hz ~ 90MHz
: 4 Digits
: 20 % to 80 % up to 1MHz
40 % to 60 % up to 10MHz |
|
| |
Impedance
Amplitude |
: 50W ± 5 %
: ± 10V into open circuit
± 5V into 50W |
|
| |
Attenuation
DC offset |
: 0dB, -20dB, -40dB, -60dB : ±10V into open circuit ±5V into 50W |
|
| |
Square wave |
|
|
| |
Rise or Fall time
Aberrations
Triangle linearity error
Sine wave distortion |
: < = 15nS at full amplitude (50W)
: < 5% of Vp at full amplitude (50W)
: 99% up to 100KHz
: < -30dB when f< 2MHz
< -25dB when f > 2MHz |
|
| |
Sync output
(TTL pulse) |
: TTL logic clock 0.2Hz ~ 90MHz
Sync output 0.2H ~ 15MHz
output impedance 50W |
|
| |
Sweep:Width
rate |
: Lin or Log During selecting range
: 0.2Hz ~ 100Hz (5sec ~ 10msec) |
|
| |
VCG characteristics |
|
|
| |
Control range
Input impedance
Func Out protection
|
: Max input 0 to 1.8Vdc for selecting range
: 2KW ±1%
: <= 20V peak on "Func Out" terminals |
|
| |
Frequency Counter |
|
| |
Range |
: 0.2Hz ~ 100MHz (standard)
100MHz ~ 2GHz (option) |
|
| |
Accuracy
Resolution |
: ±5count + time base error
: 4 Digits for internal counter
7½ Digits for external counter |
|
| |
LPF
Time base |
: Auto or manual mode
: 36.864MHz ±25PPM (23.5°±5°C)
Optional TCXO timebase (± 2.5ppm) |
|
| |
Attenuation |
: x1(ATT off); x20(ATT on) |
|
| |
Sensitivity |
|
|
| |
Standard |
: 0.2Hz ~ 75MHz/-22dbm@ 50W
typical 76M ~ 100MHz/-15dbm @50W typical |
|
| |
Option
|
: 100M ~ 2GHz/-10dbm @50W typical |
|
| |
Duty cycle measurement (TTL level
only) :
|
|
| |
Resolution
Accuracy |
: 3 Digits
: 3 % ± 10 counts
5Hz <= f <= 10MHz
|
|
| |
General
Specifications |
|
| |
Power
Operating temperature
Storage temperature:
Dimensions
Weight
Accessories |
: AC 115 / 230V; 50 / 60Hz
: 0° to 40°C; <= 80% RH
: -20°C to 70°C
: 330mm x 220mm x 150mm (11.8" x 8.7" x 5.9" )(D x W x H)
: 5 kgs